15.9.18 (1080i letter and split) Vertical linearity(V-C) and V-Position adjustment
TOP PREVIOUS NEXT
PREPARATION
Apply a 1080i pattern.
Normalize the picture settings.
Set picture mode to VIVID
PROCEDURE
Enter service mode, select DAC adjustment V-RAS and adjust pattern to center vertical position to the CRT center.
Adjust linearity data V-C so that interval of a is same as b (a=b).
If the v-position is not at the CRT center, adjust again.