Log of Modem Commands and Responses
32bit Modem Tester x9.06.01
Start Session - Tue Jun 29 21:44:33 1999
32bit Fax Tester
Copyright(C) since 1990, Jon Krahmer, All Rights Reserved.
Contact ElectraSoft, Jon Krahmer at 281-261-0307.
email: FaxMail@ElectraSoft.com or jonk@blkbox.com
Get newest versions of fax software:
www-page: http://www.ElectraSoft.com/ or http://www.blkbox.com/~jonk/

An OUT: is us talking to the FaxModem. That is the way 32bit Fax
Tester talks to your modem.

An IN : is the modem answering us. That is the way your modem
talks to 32bit Fax Tester.

Example:
 Action: Command  }Comments/Meaning:
    IN : OK       }Modem to us; YES, I supports said function.
    IN : ERROR    }Modem to us; NO, I do not supports said function.

  ----------- modem interrogation results -----------

Opened COM2 - Tue Jun 29 21:45:01 1999
COM2
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Be sure we are configured for Long Responses:
OUT: ATV1
IN : ATV1
IN : OK
Start information gathering:
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Standard information gathering:
OUT: AT&V
IN : AT&V
IN : ACTIVE PROFILE:
IN : B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C0 &D0 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 &Y0
IN : S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:050 S08:002 S09:006
IN : S10:014 S11:095 S12:050 S18:000 S25:005 S26:001 S36:007 S37:000 S38:020 S44:020
IN : S46:138 S48:007 S95:000 
IN : STORED PROFILE 0:
IN : B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C0 &D0 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 
IN : S00:000 S02:043 S06:002 S07:050 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000
IN : S36:007 S37:000 S40:104 S41:195 S46:138 S95:000 
IN : STORED PROFILE 1:
IN : B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C0 &D0 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 
IN : S00:000 S02:043 S06:002 S07:050 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000
IN : S36:007 S37:000 S40:104 S41:195 S46:138 S95:000 
IN : TELEPHONE NUMBERS:
IN : 0=                                     1=
IN : 2=                                     3=
IN : OK
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Start USRobotics style information gathering:
OUT: ATI0
IN : ATI0
IN : 28800
IN : OK
OUT: ATI1
IN : ATI1
IN : 255
IN : OK
OUT: ATI2
IN : ATI2
IN : OK
OUT: ATI3
IN : ATI3
IN : V1.100 Z201-V34_DP
IN : OK
OUT: ATI4
IN : ATI4
IN : a007880284C6002F
IN : bC60000000
IN : r1005111151012004
IN : r3000111170000000
IN : OK
OUT: ATI5
IN : ATI5
IN : 022
IN : OK
OUT: ATI6
IN : ATI6
IN : RC288DPi Rev 04BC
IN : OK
OUT: ATI7
IN : ATI7
IN : 000
IN : OK
End information gathering:
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK

         **** FaxModem class support interrogation results ****
The next [OUT] will be us asking the modem what class or classes it
supports. The following [IN] will the modem responding. The modem
should reply with all the classes that it does support. Each
supported class should be separated by a ,
Example:
 Action: Command     }Comments/Meaning:
    OUT: AT+FCLASS=? }Us to modem; What Classes do you support?
    IN : AT+FCLASS=? }Modem ECHOed back; I received this command from you.
    IN : 0,1,2,2.0   }Modem; I support [Data Class 0],
                     } [Fax Class 1], [Fax Class 2], and [Fax Class 2.0]
    IN : OK          }Modem; This conversation over without a problem.
If, in the actual question and answer, the modem responds with:
IN : ERROR then it does not support fax in a normal way.

Here is the actual class question and answer:
OUT: AT+FCLASS=?
IN : AT+FCLASS=?
IN : 0,1,2
IN : OK
The next answer should be: ERROR
OUT: AT+FCLASS=3
IN : AT+FCLASS=3
IN : ERROR
Testing Flow Control...
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Checking &Kn Flow Control:
OUT: AT&K3
IN : AT&K3
IN : OK
OUT: AT&K4
IN : AT&K4
IN : OK
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Checking &En Flow Control:
OUT: AT&E4
IN : AT&E4
IN : ERROR
OUT: AT&E5
IN : AT&E5
IN : ERROR
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Checking \Qn Flow Control:
OUT: AT\Q1
IN : AT\Q1
IN : ERROR
OUT: AT\Q2
IN : AT\Q2
IN : ERROR
OUT: AT\Q3
IN : AT\Q3
IN : ERROR
OUT: AT\Q4
IN : AT\Q4
IN : ERROR
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Checking USRobotics Flow Control:
OUT: AT&H0
IN : AT&H0
IN : ERROR
OUT: AT&H1
IN : AT&H1
IN : ERROR
OUT: AT&H2
IN : AT&H2
IN : ERROR
OUT: AT&H3
IN : AT&H3
IN : ERROR
OUT: AT&I0
IN : AT&I0
IN : ERROR
OUT: AT&I1
IN : AT&I1
IN : ERROR
OUT: AT&I2
IN : AT&I2
IN : ERROR
OUT: AT&I3
IN : AT&I3
IN : ERROR
OUT: AT&I4
IN : AT&I4
IN : ERROR
OUT: AT&I5
IN : AT&I5
IN : ERROR
OUT: AT&R0
IN : AT&R0
IN : OK
OUT: AT&R1
IN : AT&R1
IN : OK
OUT: AT&R2
IN : AT&R2
IN : ERROR
End Flow Control Test
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
OUT: AT+FCLASS=0
IN : AT+FCLASS=0
IN : OK
This FaxModem supports Class 0, Data Mode.
OUT: ATE0
IN : ATE0
IN : OK
OUT: ATE1
IN : OK
OUT: ATH0
IN : ATH0
IN : OK
OUT: ATL1
IN : ATL1
IN : OK
OUT: ATM1
IN : ATM1
IN : OK
OUT: ATS0=0
IN : ATS0=0
IN : OK
OUT: ATS0?
IN : ATS0?
IN : 000
IN : OK
OUT: ATX0
IN : ATX0
IN : OK
OUT: ATX1
IN : ATX1
IN : OK
OUT: ATX2
IN : ATX2
IN : OK
OUT: ATX3
IN : ATX3
IN : OK
OUT: ATX4
IN : ATX4
IN : OK
OUT: ATY0
IN : ATY0
IN : OK
OUT: AT&L0
IN : AT&L0
IN : ERROR
OUT: AT+FF
IN : AT+FF
IN : ERROR
OUT: AT+FMFR?
IN : AT+FMFR?
IN : ROCKWELL            
IN : OK
OUT: AT+MFR?
IN : AT+MFR?
IN : ERROR
OUT: AT+FMDL?
IN : AT+FMDL?
IN : AC/V34              
IN : OK
OUT: AT+MDL?
IN : AT+MDL?
IN : ERROR
OUT: AT+FREV?
IN : AT+FREV?
IN : V1.100 Z201-V34_DP
IN : OK
OUT: AT+REV?
IN : AT+REV?
IN : ERROR
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
OUT: AT+FCLASS=1
IN : AT+FCLASS=1
IN : OK
This FaxModem supports Class 1, Fax Mode.
OUT: AT+FRM=?
IN : AT+FRM=?
IN : 3,24,48,72,73,74,96,97,98,121,122,145,146
IN : OK
OUT: AT+FTM=?
IN : AT+FTM=?
IN : 3,24,48,72,73,74,96,97,98,121,122,145,146
IN : OK
OUT: ATE0
IN : ATE0
IN : OK
OUT: ATE1
IN : OK
OUT: ATH0
IN : ATH0
IN : OK
OUT: ATL1
IN : ATL1
IN : OK
OUT: ATM1
IN : ATM1
IN : OK
OUT: ATS0=0
IN : ATS0=0
IN : OK
OUT: ATS0?
IN : ATS0?
IN : 000
IN : OK
OUT: ATX0
IN : ATX0
IN : OK
OUT: ATX1
IN : ATX1
IN : OK
OUT: ATX2
IN : ATX2
IN : OK
OUT: ATX3
IN : ATX3
IN : OK
OUT: ATX4
IN : ATX4
IN : OK
OUT: ATY0
IN : ATY0
IN : OK
OUT: AT&L0
IN : AT&L0
IN : ERROR
OUT: AT+FF
IN : AT+FF
IN : ERROR
OUT: AT+FMFR?
IN : AT+FMFR?
IN : ERROR
OUT: AT+MFR?
IN : AT+MFR?
IN : ERROR
OUT: AT+FMDL?
IN : AT+FMDL?
IN : ERROR
OUT: AT+MDL?
IN : AT+MDL?
IN : ERROR
OUT: AT+FREV?
IN : AT+FREV?
IN : ERROR
OUT: AT+REV?
IN : AT+REV?
IN : ERROR
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
OUT: AT+FCLASS=2
IN : AT+FCLASS=2
IN : OK
This FaxModem supports Class 2, Fax Mode.
OUT: AT+FDIS=?
IN : AT+FDIS=?
IN : (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7)
IN : OK
OUT: ATE0
IN : ATE0
IN : OK
OUT: ATE1
IN : OK
OUT: ATH0
IN : ATH0
IN : OK
OUT: ATL1
IN : ATL1
IN : OK
OUT: ATM1
IN : ATM1
IN : OK
OUT: ATS0=0
IN : ATS0=0
IN : OK
OUT: ATS0?
IN : ATS0?
IN : 000
IN : OK
OUT: ATX0
IN : ATX0
IN : OK
OUT: ATX1
IN : ATX1
IN : OK
OUT: ATX2
IN : ATX2
IN : OK
OUT: ATX3
IN : ATX3
IN : OK
OUT: ATX4
IN : ATX4
IN : OK
OUT: ATY0
IN : ATY0
IN : OK
OUT: AT&L0
IN : AT&L0
IN : ERROR
OUT: AT+FF
IN : AT+FF
IN : ERROR
OUT: AT+FMFR?
IN : AT+FMFR?
IN : ROCKWELL            
IN : OK
OUT: AT+MFR?
IN : AT+MFR?
IN : ERROR
OUT: AT+FMDL?
IN : AT+FMDL?
IN : AC/V34              
IN : OK
OUT: AT+MDL?
IN : AT+MDL?
IN : ERROR
OUT: AT+FREV?
IN : AT+FREV?
IN : V1.100 Z201-V34_DP
IN : OK
OUT: AT+REV?
IN : AT+REV?
IN : ERROR
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
OUT: AT+FCLASS=2.0
IN : AT+FCLASS=2.0
IN : ERROR
This FaxModem does not support Class 2.0, Fax Mode.
Reset the modem:
OUT: AT&F
IN : AT&F
IN : OK
Closed COM2 - Tue Jun 29 21:45:42 1999
End Session - Tue Jun 29 21:45:42 1999